Read your manual carefully and pay attention to every step. Knowing exactly how your system works is what keeps it running safely and prevents damage from incorrect use.
Before you start
Welcome
In the box
| UV XL | UV XL unit, with 1 extra hose for it |
|---|---|
| UV Basic | UV Basic unit, with its two ends U1 and U2 |
| Ozone | Ozone unit |
About the UV XL
UV XL specifications
| Type | 304 stainless steel ultraviolet water disinfection system |
|---|---|
| Function | Disinfects bacteria, viruses, moulds and algae in water |
| Designed for | 6–55 W |
| Consumed power | 8–22 W |
| Input | 110 V 50/60 Hz or 220 V 50/60 Hz |
| Lamp lifespan | 8,000 hours |
About the UV Basic
- 1Lamp housing
- 2Explosion-proof quartz glass
- 3UV-C light tube
About the Ozone
You will also need (not included)
| Water hose | Long enough to reach from a tap to the AirTub, to fill it. |
|---|---|
| Power | A single power outlet. |
| Power | A power strip with 2 outlets: AirTub and UV. |
| Power | A power strip with 2 outlets: AirTub and Ozone. |
| Power | A power strip with 3 outlets: AirTub, UV and Ozone. |
Handling the chiller
Hygiene
Safety & placement
Placement and operation
Install only in a well-ventilated area (at least natural ventilation) so the chiller's hot air can escape. Never in enclosed cabinets or small unventilated spaces.
At least 30 cm free around the chiller on all sides, and at least 40 cm at the back, from any wall or object.
Stable, level surface in the shade. Outdoors, always under a roof, canopy or balcony: the chiller is not waterproof. No direct sunlight. Ambient temperature 0–38°C.
Never set the chiller below 3°C: water can freeze inside the system and damage the chiller.
Grounded installation with an RCD / GFCI only; if unsure, ask a licensed electrician. Where voltage fluctuates use a voltage stabiliser, surge-protected power strip or UPS. Never touch plugs with wet hands.
Keep the UV and Ozone units away from flammable materials.
Clean, drinkable water that meets EU drinking-water standards. With hard water (high minerals or salt), have it tested and treated first, or it can cause blockages, corrosion or failure.
Never run without water, never run the chiller without the pump connected and powered, never run with closed valves. If the pump stops, switch the chiller off immediately.
Always supervise children and pets around the system.
Tub care
Installation
Unbox and inflate
Place the tub
Top of the chiller
Tub valves
- 1Upper tub valve
- 2Lower tub valve
Hoses
- Hose end CLower tub valve
- Hose end DChiller IN
- Hose end AChiller OUT
- Hose end BUpper tub valve
- Hose end BUV IN
- UV OUTUpper tub valve
- UV OUTOzone S2, Side B (IN)
- Hose end BOzone S2, Side B (IN)
- Ozone S1, Side A (OUT)Upper tub valve
Connect the UV Basic
- U1Upper tub valve
- U1Ozone fitting S2, Side B (IN)
UV Basic with Ozone
Connect the UV XL
Connect the Ozone
- Chiller OUTS2, Side B (IN)
- UV XL OUTS2, Side B (IN)
- UV Basic U1S2, Side B (IN)
Your connection
Close the valves
Pump cable
Power cable
Using Smart Control?
| AirTub | Connect the AirTub to the Smart Control. |
|---|---|
| Power strip | Connect the power strip (AirTub and your extras) to the Smart Control. |
Fill with water
Release the air
Start the system
Set the temperature
Other settings (P0–P6)
| P0 = C | Cooling or heating mode. This model is for cooling. |
|---|---|
| P1 = 3.0 | Temperature difference: after reaching the target, cooling restarts this many degrees higher (target 7°C → stops at 7, restarts at 10). |
| P2 = 110 | High-temperature warning for the chiller box: above this value the chiller does not operate. |
| P3 = -50 | Low water temperature warning. |
| P4 = -2 | |
| P5 = 3 | Protection delay: the chiller starts 3 minutes after switching on, protecting it from rapid power fluctuations. |
| P6 = C | Celsius (C) or Fahrenheit (F). |
Using your AirTub
Away for 3–4 days or more
Winter outdoors
UV XL: good to know
Maintenance
Maintenance schedule
| Every week | Check the water (colour, clarity, smell) and the filter. Replace the filter if it has reached level 2. |
|---|---|
| Every 30–40 days | Replace the filter. |
| Not used for 2–3 days | Open the lid and stir the water by hand in circles for 20–30 seconds. |
| Every 30–40 days | Change the water and clean the tub. |
| Every 2–3 months | Change the water and clean the tub (depending on how often and how cleanly it is used). |
| Every 2–3 months | Change the water and clean the tub (depending on how often and how cleanly it is used). |
| Every 3–4 months | Change the water and clean the tub (depending on how often and how cleanly it is used). |
| Every 6 months | Clean the internal washable filter and blow the dust out of the chiller. |
| Every 6 months | Clean the internal washable filter and blow the dust out of the chiller. |
| Every 6 months | Blow the dust out of the chiller. |
| About every 330 days | Replace the UV XL lamp (8,000 hours).Contact |
| About every 208 days | Replace the UV Basic lamp (5,000 hours). |
Filter check: priority no. 1
1 · OKWorks fine
2 · REPLACENeeds cleaning or replacement now
3 · BADReplace as soon as possible: it can damage the system
4 · VERY BADReplace now: it will damage the systemReplace the filter
Change the water and clean the tub
Fresh water
Every 6 months: blow out the dust
Every year: refrigeration technician
| UV XL | No maintenance needed. Only the lamp is replaced at the end of its lifespan (8,000 hours). |
|---|---|
| UV Basic | No maintenance needed. Only the lamp is replaced at the end of its lifespan (5,000 hours). |
| Ozone | No maintenance needed. |