INTRODUCTION
The UV Disinfection Module is designed to eliminate bacteria, viruses, and other microorganisms using ultraviolet (UV-C) light. It provides an effective and chemical-free method of sterilization for various applications. This manual will guide you through its installation, operation, and maintenance to ensure optimal performance and safety.
*Lifespan: 8000 hours

Ultraviolet Water Disinfection System
-
Name: 304 Stainless Steel Ultraviolet Water Disinfection System
-
Applications: Drinking water, food processing, medical, and industrial, etc.
-
Function: Disinfect bacteria, viruses, molds, and algae in water.
-
Design for: 6–55 W
-
Consumed Power: 8 W – 22 W
-
Input: 110 V 50/60 Hz or 220 V 50/60 Hz
SAFETY & INFORMATION
Electrical Safety
-
Warning: Do not plug in or operate unless the electrical panel in your location is equipped with a Residual Current Device (RCD) – also known as a Ground Fault Circuit Interrupter (GFCI) – and proper grounding. By law and for your own safety, all homes and facilities must have RCD/GFCI protection installed in their main electrical panels. If you are unsure what this means, or if your panel does not include this protection, do not connect your IceBath. Instead, consult a licensed electrician to install the necessary safety device.
-
Voltage Stability – Important Notice
If your area has a history of voltage fluctuations from the electricity provider, we recommend connecting the IceBath to the socket through a voltage stabilizer, a surge-protected power strip, or a UPS (Uninterruptible Power Supply). For more information on the appropriate solution, please consult a qualified electrician in your area.
⚠️ In case any damage occurs to the IceBath due to voltage fluctuations, it will not be covered by the warranty.
-
Warning ⚠️ : UV-C Light Can Be Harmful
-
When replacing the lamp (inside), do not look directly at the UV light when the module is operational.
-
Ensure the module is powered off before performing maintenance.
-
Keep the module away from flammable materials.
-
Follow all local regulations regarding UV light usage and disposal.
-
CABLE CONNECTIONS
-
To operate the AirTub with the UV system, you will need a power strip with at least two sockets. One socket is for the AirTub, and the other is for the UV system. It’s recommended to connect both devices to a single power strip rather than separate outlets, allowing you to control them simultaneously.
*The power strip shown in the image is not included in our package, you will need to use one of your own. -
Once you connect the UV to the power, the screen will turn on, and you will see an indicator. By pressing the button on the right side, you can change the settings. This setting determines how many consecutive hours the UV lamp will operate within a 24-hour period. SET 24H

-
The UV lamp has a lifespan of 8,000 hours, so make a note of when it was purchased and when it will need to be replaced. So the lamp will need to be replaced in approximately 330 days.
COMPONENTS

UV XL - SETUP
Step 1: Disconnect the hose only from the upper valve of the Tub (A in the image) and connect it to the “IN” adapter of the UV system.
This means that the hose coming from the “OUT” side of the chiller will now be connected to the “IN” side of the UV unit.

Step 2: Connect the HOSE 4 (included inside the UV package) from the “OUT” side of the UV system to the upper valve of the Tub. In essence, the UV system is installed between the chiller and the Tub.
The final result should look like the setup shown in the image.
The final setup should match the configuration shown in the image:
• Hose 1: From the lower valve of the Tub to the “IN” side of the filter
• Hose 2: From the “OUT” side of the filter to the “INLET” of the chiller
• Hose 3: From the “OUTLET” of the chiller to the “IN” side of the UV system
• Hose 4: From the “OUT” side of the UV system to the upper valve of the Tub

UV+OZON - SETUP
Follow this step only if you have purchased both the UV and the Ozone system.
After completing the UV system installation, follow the next step below to connect the Ozone system as well.
OZONE COMPONENTS

Step 1: Disconnect Hose 4 from the upper valve of the Tub and connect Hose 4 to SIDE B of the Ozone unit.

Step 2: Connect SIDE A of the Ozone unit to the upper valve of the Tub (where you previously disconnected Hose 4).
In essence, the OZONE system is installed between the UV and the Tub.
The final result should look like the setup shown in the image.
The final setup should match the configuration shown in the image:
• Hose 1: From the lower valve of the Tub to the “IN” side of the filter
• Hose 2: From the “OUT” side of the filter to the “INLET” of the chiller
• Hose 3: From the “OUTLET” of the chiller to the “IN” side of the UV system
• Hose 4: From the “OUT” side of the UV system to the SIDE B of the OZONE unit
• SIDE A of the OZONE unit should be attached on the upper valve of the Tub

LAMP REPLACEMENT
On the UV lamp power supply there is a small indicator light. As long as it is green, the lamp is working correctly. When, after some time, the lamp reaches the end of its lifespan, the indicator will turn red. At that point, the lamp must be replaced. Please contact us so we can send you a replacement.
-
Unplug the entire system from the power supply.
-
Close all valves of the system.
-
There is no need to disconnect any hoses.
When replacing the lamp, no water will flow from the UV unit because the lamp does not come into contact with the water inside the system.

To replace the internal UV lamp, please watch the video below.
System Operation
-
Use only with visually clear water (not colored, cloudy, or turbid).
-
Water quality limits: Ambient ≤45°C | Iron <0.3 ppm | Hardness ≤120 mg/l | Turbidity <1 NTU | Manganese ≤0.05 ppm | UV Transmittance >75%.
-
Check installation before connecting to power.
-
Do not install if the UV lamp or sleeve tube is broken.
-
Designed for continuous operation – frequent switching reduces lamp life.
-
If the unit falls into water: turn off power immediately and retrieve it. Do not reuse if submerged.
-
Do not operate with damaged cord, plug, or after impact/damage.
-
Must be installed after the filter on the return line.
-
If exposed to freezing conditions: disconnect water supply and drain completely.
Important Safeguards
-
⚠️ UV light is invisible but harmful to eyes and skin.
-
Do not look directly at the lamp or remove it under power.
-
Wear safety goggles if observation is necessary.
-
Always follow basic safety precautions to avoid fire or electric shock.
-
Ensure a leakage protection switch is installed before use.
MEDICAL DESCLAIMER
Our ice baths are designed for wellness and recovery but are not a substitute for medical treatment. We hold no responsibility for any medical issues arising from their use. Users of all ages, including children, pregnant individuals, the elderly, and even athletes, should consult a physician before using this product to ensure cold therapy is safe for them. Please note that by using this product, users assume full responsibility for any associated health risks.
WARRANTY & SUPPORT
The UV Disinfection Module is covered under a 1 year warranty for manufacturing defects.
❌ Exclusions:
-
Misuse or unauthorized modifications
-
Improper maintenance
-
Physical damage due to external factors
If you encounter any issues that cannot be resolved using this guide, please contact our support team